Producent | Not Specified | Part Number | 199000 (199000) |
Specifications | Conrad GX107 GSM Remote Switch And Monitoring Module With GPS Function |
Unit Price | 177,46 EUR |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | Conrad GX107 GSM Remote Switch And Monitoring Module With GPS Function Technical data Housing protection class: IP66Switching power: 8 A/250 V/AC, 5 A/30 V/DCOperating temperature: -20 to +75 °C Type GX107 Operating voltage 5 - 32 Vdc Operating voltage 5 Vdc, 32 Vdc No. of relay outputs 2 No. of digital inputs 1 No. of digital inputs 1 Function Notify, Switch Category GSM module T 43 mm Length 88 mm Width 64 mm Protection type IP66 Max. current consumption 230 mA Standyby current 10 mA Weight 165 g Manufacturer part No. 199000 Highlights & details Switch electrical systems remotely via SMS text message instructionsModule can send SMS notifications based on signals at its inputs and user requestsTakes a regular mobile phone SIM card and its phone numberIn-call function switches output(s) when incoming call receivedCan be expanded with GPS antenna for global positioning functionsIntegrated LiPo battery for backup power Description FunctionalityUse the Conrad GX107 GSM module to switch and monitor electrical appliances and systems remotely. Send the remote switch commands by SMS text message or in-bound phone call and it sends status notifications via SMS text message based on the signals at its inputs and commands it has received. The GX107 takes a regular SIM card from any mobile phone provider and uses the GSM (mobile phone) network. When the GX107 is expanded with a GPS antenna, it offers the additional feature of sending GPS coordinates by SMS text message and even alarm notifications when it is take outside permitted areas!ApplicationsSwitching: - Two isolated relay outputs mean the GX107 module can remotely switch regular 230-240V mains powered appliances or max 24Vdc devices. This could include, but is not limited to, heating or cooling systems, garage doors, security lighting, access control. Practically any device can be controlled and monitored from anywhere in the world via SMS text message!Monitoring: - Appliances such as burglar alarms, smoke detectors and motion detectors can be connected to the GSM module's digital inputs, whereby the GX107 sends out SMS text message notifications based on high or low incoming voltage signals. Global positioning: -Inputs / Outputs OverviewOne NO relay output (8A/250Vac or 5A/24Vdc)One transistor output (300mA/32Vdc)One digital optocoupler input (0-12Vdc)One analogue input for e.g. temperature sensor (max 2.8Vdc)INCALL Inbound Call OutputThe GX107's INCALL function can be assigned to the module's relay or transistor output. Two modes are available: Toggle, the output is switched when the module receives an incoming call (call once for on, once for off), or Time, the output is activated for pre-configured set time period. The time period can be set in intervals of secs anywhere between 1 and 43,200 seconds (12 hours).SMS Controlled OutputThe GSM module's second relay output can be activated or deactivated based on an incoming SMS text message command. This is not a timer relay. The texted command SMS1=1 activates the relay, SMS1=0 deactivates the relay. This output also features a red signal LED to show when the relay is active. Digital InputsTwo independent digital (optocoupler) inputs can be configured so that the GSM module sends an individual SMS notification only when the voltage at an input drops below 2.5V, only when it increases above 2.5V or when any change is detected. 2.5V=1. EnclosureThe GSM remote switch and monitoring module is supplied with a weatherproof enclosure that meets IP54. When the provided cable glands are used, the enclosure meets IP66.The Conrad GX107 module uses the GSM (mobile phone) network to remotely switch and monitor electrical systems, from anywhere in the world. Monitoring of stationary and moving objects. Determine the measured voltage/temperature, the status of the electrical signals and optionally the current GPS-position of the object via SMS at all times. Switch one of the 2 switching outputs at all times conveniently via SMS or via a call. Get information via SMS and e-mail, when, for instance the power supply breaks down, the temperature goes above or below the set values or optionally, when the monitored object moves outside of the set GPS-coordinates. By using the AREA-function you can specify GPS-corridors, in which the object may be present. Upon leaving a warning message is sent immediately to all the stored telephone numbers (SMS). Get the current GPS-position of your monitored object at regular intervals.For a full list of this module's inputs/outputs, please see the list below under 'Features'.Applications:· Monitoring and remote control of heating, air conditioning, cooling systems· Remote control of doors and garage doors· Control and monitoring of motion or fire detectors, level sensors· Monitoring the position of moving objects· and more. Features 1x ADC / temperature sensor input1x digital optocoupler input1x 250Vac/8A relay output1x transistor outputStatus queryEnglish/German language optionSpecify up to 6 phone numbers for SMS alertSpecify an E-mail address for alertsActivate/Deactivate alertsChanging the device nameSwitches over an outputSpecify alert at digital input as per changes in statusSpecify two threshold values for analogue inputSwitch a digital output on callScan GPS locationSpecify 10 geographical zonesSpecify alert with exiting a zone. Included in delivery GX107 GSM remote switch and monitoring moduleBuilt-in 1100mAh LiPo batteryIntegrated GSM antennaIP66 enclosure with cable glands and sealing plugsUser manual. To make use of the GX107's GPS functionality, please order the GPS antenna listed under the 'Accessories' tab |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|