440R-N23135 Allen Bradley Guardmaster Minotaur 440-R Safety Relay, Single Channel, 24 V ac/dc, 3NO Safety, NC Auxiliary

ProducentAllen Bradley Guardmaster
Part Number

440R-N23135 (440RN23135)

Specifications

Minotaur 440-R Safety Relay, Single Channel, 24 V ac/dc, 3NO Safety, NC Auxiliary

Unit Price175,99 EUR
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionAuxiliary ContactsNC Contact Current Rating5 A Contact Voltage Rating24 V dc, 250 V ac Control Voltage24 V ac/dc Depth22.5mm Dimensions114.5 x 99 x 22.5 mm FunctionLight Beam/Curtain, Safety Switch/Interlock Length114.5mm Maximum Operating Temperature+55°C Minimum Operating Temperature-5°C Mounting StyleDIN Rail Mount Normal State Configuration3NO/NC Number Of Auxiliary Contacts1 Number of Channels1 Pole Configuration3P (Safety), SP (Auxiliary) Power Rating2 W RangeMinotaur Reset MethodMonitored Safety CategoryPLe per ISO 13849-1 (Safety) Safety Contacts3NO Series440-R Supply Voltage24 V ac/dc Terminal TypeScrew Width99mm Product Details Minotaur MSR127RTP Safety Relay, Single Channel The MSR127RTP is a single function safety relay that can be connected in three different input wiring configurations: one normally closed, two normally closed, or with two PNP connections from a light curtain. When connected in the two normally closed configuration, the MSR127RTP checks for cross faults across the two inputs. When connected to light curtains, the light curtain must perform the cross fault detection.The MSR127RP relay has a monitored manual reset whereas the MSR127TP relay has an automatic/manual reset. Models with automatic/manual reset can have the reset jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop. Models with monitored manual reset provide checking of the output monitoring circuit.The outputs of the relay include three normally open safety-rated outputs as well as one normally closed auxiliary output. The safety outputs have independent and redundant internal contacts to support the safety function. The auxiliary output is a non-safety output intended to provide an external signal about the status of the safety outputs. Can be connected in three different input wiring configurations: 1 N/C, 2 N/C, or with 2 PNP connections from a light curtain. When connected to light curtains, the light curtain must perform the cross fault detection.Stop category 0Cross fault monitoringMonitored or automatic resetRemovable terminalsLight curtain, E-stop or safety gate applicationsCat. 4 per EN954-1 Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1. Safety Relay
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com