CALYS 50 Aoip Instrumentation Aoip Instrumentation CALYS 50 Multi Function Calibrator 50V 50mA 1000bar
| |
|
Producent | Aoip Instrumentation | Part Number | CALYS 50 (CALYS50) |
Specifications | Aoip Instrumentation CALYS 50 Multi Function Calibrator 50V 50mA 1000bar |
Unit Price | 1829,13 EUR |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | Battery Life8 h Battery TypeLithium-ion Dimensions210 x 110 x 50mm Maximum Current Measurement50mA Maximum Operating Temperature50°C Maximum Pressure Measurement1000bar Maximum Voltage Measurement50V Minimum Operating Temperature-10°C Model Number pCALYS 50 Port Connections3mm Wires, 4 mm Terminal, USB Power SourceBattery Weight900g Product Details CALYS 50 calibrator Maintenance tool which gathers all of the signals in the manufacturing process: voltage, current, resistance, temperature using resistance probes and thermocouples, Frequency, counting and measurement and simulation of dry contacts.Simultaneous measurement and emission.Double display (measurement / emission) screen with indication of date / time and ambient temperature.'Easyconnect", ultra simple connection system, which accepts sockets, bare wires, terminals and banana plugs as well as flat thermocouple connectors.Graphic screen display with date and time, backlit with adjustable contrast. Selectable display resolution of 1, 2 or 3 digits after the decimal point.Display of measurement statistics: Min, Max and Average.Emission of ramps and increments to test the linearity and the range of transmitters, with retarder function.Integrated valve test.Scaling for quadratic and linear signals.Scaling for sensor correction.Compatible with HART transmitters.USB port for downloading software.Supplied with measurement wires, strap and stand. VOLTAGE Measurement 100 mV 0.001 mV 0.013 % + 2 μV 1 V 0.01 μV 0.013 % + 20 μV 10 V 0.1 μV 0.013 % + 200 μV 50 V 01 mV 0.013 % + 2 mV Emission 100 mV 0.001 mV 0.013 % + 2 μV 2 V 0.01 μV 0.013 % + 20 μV 20 V 0.1μV 0.013 % + 200 μV CURRENT Measurement 50 mA 0.001 mA 0.018 % + 2 μA Emission 24 mA 0.001 mA 0.018 % + 2 μA RESISTANCE Measurement 400 ohms 0.001 ohm 0.012 % + 10 mohms 4000 ohms 0.01 ohms 0.012 % + 100 mohms Emission 400 ohms 0.001ohm 0.017 % + 20 mohms 4000 ohms 0.01 ohms 0.017 % + 200 mohms FREQUENCY Measurement 20 KHz 0.01 Hz 0.005 % Emission 10 Hz 0.01 Hz 0.005 % 10 HZ 10 Hz 0.005 % PT100 Measurement -210 → +850 °C 0.01 °C 0.012 % + 0.05 °C Emission -210 → +850 °C 0.02 °C 0.017 % + 0.08 °C Thermocouple K Measurement -250 → +1372 °C 0.05 °C 0.013 % + 0.05 °C Emission -250 → +1372 °C 0.05 °C 0.013 % + 0.05 °C Multifunction Calibrators |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|