150499 Burkert Burkert Solenoid Valve 150499, 2 port , NC, 230 V ac, 1/2in

ProducentBurkert
Part Number

150499 (150499)

Specifications

Burkert Solenoid Valve 150499, 2 port , NC, 230 V ac, 1/2in

Unit Price313,79 EUR
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionBody MaterialPPS Connection1/2 in G Female Connection GenderFemale Connection Size1/2in Default Valve PositionNC Flow Factor Kv2.2m³/h Maximum Operating Temperature+55°C Maximum Working Pressure10bar Minimum Operating Temperature0°C Number of Ports2 Operating Temperature Range0 → +55 °C Orifice Diameter0.8mm Series6038 Suitable ApplicationsNeutral Media, Steam Supply Voltage230 V ac Thread Standard or Connection TypeG Type2/2 Product Details 6038 range - 2-way angled solenoid valve for steam Solenoid valve for neutral media and steamClosed without power (spring actuator)Switching without differential pressure (0 → 10 bar)Low media redirection means a stable aggregated stateSimple coil replacement by loosening a central nutCoil can be rotated through 360° Pressure range: 0 → 10 bar Temperature of medium: -10 °C → +180 °C Amb. temperature: max. +55 °C Housing material: Gunmetal Sealing material: PTFE Coil material: Epoxy Elect. Capacity: 106 VA start‑up, 38 VA operation Protection rating: IP65 with device socket Cable connection: G1/2 Nominal width: 12 mm KV value:Switching frequency:Rated operating current type: 2.2 m3/happrox. 30/minContinuous operation 100% ED Weight: 900 g Two Way Inert Gases and Fluid Valves Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com