PAD-500 CONRAD COMPONENTS Conrad Components PAD-500 PAD 500 Phase Section Control 500 W

ProducentCONRAD COMPONENTS
Part Number

PAD-500 (PAD500)

Specifications

Conrad Components PAD-500 PAD 500 Phase Section Control 500 W

Unit Price25,26 EUR
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionConrad Components PAD-500 PAD 500 Phase Section Control 500 W Technical data Power: max. 500 W Type PAD 500 Casing Ready-to-use board Operating voltage 230 Vac Power 500 W Operating temperature (min.) 0 °C Max. operating temperature +40 °C Length 116 mm Width 42 mm Height 29 mm Type PAD 500 Manufacturer Conrad Components Operating voltage 230 Vac Temperature range 0–40 °C Highlights & details Optimum for electronic transformers (EVG)Power can be adjusted via potentiometerSoft start-up Description In case of a reverse phase conrol the current is switched on immediately after the zero-crossing of the alternating current, and switched off before the next zero-crossing. This takes place exactly in reverse in case of phase control. In most of the "dimmers" made with a triac the load current is "ignited" only after the zero-crossing, and this flows till the next zero-crossing. Both the switching versions are suitable for regulating ohmic loads. If there are phase displacements (as in the case of capacitive or inductive consumers), then there are enormous restrictions - caused by the current or voltage surges that appear. While the phase control is suitable, for instance, for electric motors, capacitive loads mostly lead to a destruction of the dimmer.The essentially more complex switching technology of the reverse phase control, however, is in a position to regulate also capacitive loads, such as dimmable electronic transformers (EVGs) along with ohmic consumers like incandescent lamps or R7s halogen rod lamps. These transformers are preferably used in the low-voltage halogen and LED-lighting technology. Together with a linear 47 kΩ potentiometer (not included in the delivery) a power pf up to maximum 500 W can be adjusted continuously. Regardless of the power consumption maximum two electronic transformers can be connected each with max. 250 W. Not suitable for inductive loads like conventional transformers and electric motors of any kind. Please pay attention to the data sheet provided for download. Connection to be made only by certified electricians.
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com