|
Producent | Gent | Part Number | 75585-08 (7558508) |
Specifications | 8 Zone Auto Reset Fire Alarm Control Panel |
Unit Price | 508,32 EUR |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | Auto ResetYes Control TypesCancel, Disable Zone, Fault Buzzer, Lamp Test, Reset, Silence Alarms, Sound Alarms Number of Zones8 Silent Maintenance TestingYes Product Details Alarm System Control Panel Fire alarm control panels designed to comply with EN54 Parts 2 & 4 and suitable for installations meeting BS5839 Part 1. Easy to install, with clear fire/fault indicationProgrammable with option for zone and sounder configurationsIntegral PSU and battery support for up to 8 alarms sounder circuits, 2 auxiliary relay contacts and zone disable facilitySuitable for automatic detectors, manual call points, or a combination of bothIncludes an external evacuation facilityDetectors and manual call points can be wired in any orderDetector removal monitoring via diode baseAuto reset function and silent maintenance tests configured by each individual zoneAny zone can be selected for special fire activities, zones may be disabled at any timeKeypad access with password protectionBatteries provide 72 hour standby Detection circuits 24 (max) per zone @ 16V (min quiescent)20mA @ 7V across trigger devices27mA @ 0V fire voltage Alarm circuits 2 per panel (min), 8 on 8 Zone panel1A (max) load on 1&2 Zone panels1·5A (max) load on 4&8 Zone panels Auxilary relay contacts 1 set N/O and 1 set N/C, rated 1A @ 24Vdc Class Change 1 pair N/O un-monitored terminals operated via external remote Fault Monitoring Zones; Open/Short circuit via end-of-linecapacitor and polarising diodeAlarm Circuits: Open/Short circuit with 22kΩend-of-line resistorOther; Earth/Fault, battery charger, mainspower and fuse state Controls Sound Alarms, Silence Alarms, Reset, CancelFault Buzzer, Lamp Test, Disable Zone Batteries (not supplied) 1&2 Zone (2x12V 2Ah 597-813)4&8 Zone (2x12V 2.8Ah 597-829) Fire Alarm Sys Comp - Gent Gent Smoke and Heat Detectors Providing a comprehensive range of sensing devices for use on DC monitored, automatic fire detection systems, this series of smoke and sensing devices has been designed to provide easy installation and maintenance with full detector interchangeability. Particular emphasis has been given to the overall series design, in order to minimise the incidence of false alarms from electrical or other sources of interference.The heat detectors are designed to meet the requirements of BS 5445: Part 2 as recommended by BS 5839: Part 1: 1980, and the smoke detectors are designed to meet the requirements of BS 5446: Part 1 and the draft European standard PrEN54 Part 7. Each detector can be fixed to a mounting base (available separately) which is suitable for two wire circuits using surface or concealed wiring methods. The detector is fitted to the base by a simple plug-in and twist locking action. The design of the base unit ensures ease of installation with easily accessible terminals. Four slotted fixing holes are provided to allow fixing at centres of 50mm and 60mm suitable for conduit boxes. The holes also enable the detector to be positioned so that the LED indicator (illuminated when the detector is triggered) is visible from a doorway, etc. Note Base sold separately see RS stock number 175-630 |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|