Producent | Janitza | Part Number | 5219001 (5219001) |
Specifications | Janitza UMG 511 Mains-analysis device, Mains analyser CAT III 600 V |
Unit Price | 3196,58 EUR |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | Power quality analyser UMG 511 Technical data Measure interval: 200 msCurrent measuring range: Current transformers x / 5 A or x / 1 A, also suitable for medium voltage systems Display Active-Matrix Power supply 95 - 265 V/AC, 130 - 370 A Vdc Weight 1 kg Calibrated to Manufacturer standards Width 144 mm Height 144 mm Highlights & details remote monitoringcontinuous monitoring of voltage quality?Ethernet Gateway for mentioned measure points Description For the monitoring of voltage quality as per standard norms. It is recorded and evaluated as total quality parameter, e.g. Flicker, interruptions with disturbance function, Transienten, overtones, upto 63ten, Power-on current etc. Several communication options z.B. RS 485 Modbus, Profibus, Ethernet (TCP/IP), http, FTP, SMTP, SNTP, DNS etc. enables economic and fast integration in existing communication structure. With the embedded web server, through one browser world wide access is possible. by the built-in Basic-interpreters, free access to all integrated variables is available via existing reload able Basic program (measuring valueetc.). It can be created as per user specific Basic program, where it can run 7 parallel cycles. The Software GridVis gives various evaluations with evaluations by Analyse tools as per EN 50160 und EN 61000-2-4. Features Measuring voltage quality as per DIN EN 61000-4-30Measuring process Class AFourier analyse 1. to 63.oscillation for U-LN, U-LL, I, P und QMeasuring oscillation and intermediate harmonic as per DIN EN 61000-4-7According to DIN EN 61000, 4, 15 (hospital beds)Measure in TN- and TT-power4 Voltage input meter, 4 current inputsContinuous spacing of voltage and v current inputs 20 kHzRecording of more than 2000 Measuring values pro Measuring cycle (200 ms)Recording Transienten>50 µs and storage with 16000 scanning pointsData logger/outcome saver8 digital inputs and 5 digital outputsProfibus DP/VO alternative RS 485 (Modbus RTU, Modbus-Master)EthernetProgramming application in BasicBACnet optionalAutomatic adjustment of net frequency from 15 to 70 HzLeak-proof scanning and computing: voltage L-N and L-L, star point voltage and Asymmetries L1 ...L3, Strom, total current L1 ...L3 (+N)Reactive power, effective power, apparent power, performance factor, V Bias reactive power, effective und reactive function, 1-63 harmonic THD, Pst und Plt, level- und round control signal. Included in delivery Power visualisation-Software GridVisUser manual. |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|