KANE100-1/RS Kane Kane 100 Indoor air quality analyser

ProducentKane
Part Number

KANE100-1/RS (KANE1001RS)

Specifications

Kane 100 Indoor air quality analyser

Unit Price807,58 EUR
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionBattery Life6 h Battery TypeRechargeable NiMH Best Carbon Dioxide Accuracy±10% Best Carbon Monoxide Accuracy±10% Carbon Dioxide Resolution1ppm Carbon Monoxide Resolution1ppm Data LoggingYes Dimensions200 x 90 x 45mm Display TypeLCD - Backlit Height45mm Length200mm Maximum Carbon Dioxide Level9999ppm Maximum Carbon Monoxide Level2000ppm Maximum Operating Temperature+45°C Minimum Carbon Dioxide Level200ppm Minimum Carbon Monoxide Level1000ppm Minimum Operating Temperature0°C Model Number pKANE100 Power SourceBattery Weight1kg Width90mm Product Details Kane 100-1 Ambient CO and CO2 Analyser The KANE 100-1 handheld gas analyser can measure and log ambient carbon monoxide (CO) and carbon dioxide (CO2) concentrations. It is ideal for proving that flueless gas appliances such as space heaters, water heaters and kitchen equipment are operating safely. If faulty or inadequately ventilated, these appliances generate high levels of harmful CO and CO2. It also measures CO2 for indoor air quality (IAQ) checks. Inadequate ventilation and poorly operating appliances will increase CO2 levels causing drowsiness. Two line backlit display controlled by rotary switchMeasures CO using an electrochemical sensorMeasures CO2 using a long life NDIR infra-red sensorInternal pump for fast response in ambient air or ductsSampling probe with hoseMemory facility stores up to 255 sets of readingsReadings can be logged manually or auto logged at 1 to 10 minutes intervalsInfra-red output to optional printerFitted with rechargeable NiMH batteries Parameter Range Resolution Accuracy*1 Gas Measurement       Carbon Monoxide 0-1,000ppm nominal2,000ppm max 1ppm +5ppm +5% >100ppm+10% >1000ppm Carbon Dioxide 0-4,000ppm nominal9,999ppm max 1ppm +20ppm +5% +10% >4,000ppm Storage Capacity 255 sets of test results in volatile memory     Ambient Operating Range 0°C to +40°C 10% to 90% RH non-condensing     Battery Life >6 hours from full charge     Charger Input 100-220V ac / 50-60 Hz, (supplied)     Dimensions       Weight:Handset:Probe: 755g handset with boot200 x 45 x 90mm 300mm long including handle.6mm diameter x 240mm long detachable stainless steel shaft with 2.25m long hose.     *1 Using dry gases at STP Supplied with protective rubber sleeve with magnet, sampling probe with hose, charger and carry case. Indoor Air Quality
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com