163UK-9774719 Knick Multi meters Portavo 907 Multi, Type 907 Multi Oxy Set , Description 907 Multi Oxy incl. optical oxygen sensor SE 340
| |
|
Producent | Knick | Part Number | 163UK-9774719 (163UK9774719) |
Specifications | Multi meters Portavo 907 Multi, Type 907 Multi Oxy Set , Description 907 Multi Oxy incl. optical oxygen sensor SE 340 |
Unit Price | |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | Multi meters Portavo 907 Multi The only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition. The following logging types can be selected: - Manual logging - Time-controlled logging at a fixed interval - Signal-controlled logging of measured value and temperature - Combined time and signal-controlled logging - Threshold-controlled logging with pre-trigger The data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status. User-friendly software Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help. - High-resolution color graphic display - Transflective and sunlight readable - Li-ion battery - Micro USB port and Paraly SW 112 software - A sensor quiver protects the sensor from damage and drying out - The high-performance polymer housing ensures low water absorption and high impact resistance - Intelligent data logger with 10,000 entries and graphical representation - Memosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors) - The mineral glass display is perfectly readable even after years Specifications pH/mV input (analogue): pH: mV: -2 to 16 ( -1300 to 1300 ( Temperature input: Temperature with NTC 30 kÙ: Temperature with Pt 1000: -20 to +120°C ( -40 to +250°C ( Memosens input (ISFET): pH: mV: -2.000 to +16.000 ( -2000 to +2000 ( -50 to +250°C ( Memosens input, Redox: mV: Temperature range: -2000 to +2000 ( -50 to +250 °C ( Conductivity measuring range: 0.001µS/cm (c 0.01µS/cm (c=0.05 to 0.2cm-1) 0.1µS/cm (c>0.2cm-1) TDS: Salinity: Resistivity: Concentration: 0 to 1999mg/l 0.0 to 45.0g/kg 00.00 to 99.99MÙ x cm 0.00 to 9.99 (w/w) % Conductivity input (analogue): Measuring range with Sensor SE 202: Sensor SE 204: 2-electrode sensors: 4-electrode sensors: 0.01 to 200ìS/cm 1ìS/cm to 500mS/cm 0.1ìS x c to 200mS x c 0.1ìS x c to 1000mS x c Temperature input: Measuring range with NTC 30 kÙ: Measuring range with Pt 1000: -20 to +120°C -40 to +250°C Conductivity input, Memosens: Measuring range Sensor SE 215 MS: 10ìS/cm to 20mS/cm Conductivity input: Temperature compensation: nLF: linear 0 to 20%/K, ref. temp. adjustable 0 to 120 °C Memosens input, oxygen (optical): Saturation: Concentration: 0.000 to 1000.0% 000ìg/l to 100.00mg/l Partial pressure: Temperature measuring range: 0.0 to 2000mbar -20 to+150°C Power supply: Protection class acc. to DIN EN 60529: 4 x AA IP66/67 with pressure compensation Type 907 Multi Oxy Set Description 907 Multi Oxy incl. optical oxygen sensor SE 340 |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|