163UK-9774719 Knick Multi meters Portavo 907 Multi, Type 907 Multi Oxy Set , Description 907 Multi Oxy incl. optical oxygen sensor SE 340

ProducentKnick
Part Number

163UK-9774719 (163UK9774719)

Specifications

Multi meters Portavo 907 Multi, Type 907 Multi Oxy Set , Description 907 Multi Oxy incl. optical oxygen sensor SE 340

Unit Price
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionMulti meters Portavo 907 Multi The only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition. The following logging types can be selected: - Manual logging - Time-controlled logging at a fixed interval - Signal-controlled logging of measured value and temperature - Combined time and signal-controlled logging - Threshold-controlled logging with pre-trigger The data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status. User-friendly software Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help. - High-resolution color graphic display - Transflective and sunlight readable - Li-ion battery - Micro USB port and Paraly SW 112 software - A sensor quiver protects the sensor from damage and drying out - The high-performance polymer housing ensures low water absorption and high impact resistance - Intelligent data logger with 10,000 entries and graphical representation - Memosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors) - The mineral glass display is perfectly readable even after years Specifications pH/mV input (analogue): pH: mV: -2 to 16 ( -1300 to 1300 ( Temperature input: Temperature with NTC 30 kÙ: Temperature with Pt 1000: -20 to +120°C ( -40 to +250°C ( Memosens input (ISFET): pH: mV: -2.000 to +16.000 ( -2000 to +2000 ( -50 to +250°C ( Memosens input, Redox: mV: Temperature range: -2000 to +2000 ( -50 to +250 °C ( Conductivity measuring range: 0.001µS/cm (c 0.01µS/cm (c=0.05 to 0.2cm-1) 0.1µS/cm (c>0.2cm-1) TDS: Salinity: Resistivity: Concentration: 0 to 1999mg/l 0.0 to 45.0g/kg 00.00 to 99.99MÙ x cm 0.00 to 9.99 (w/w) % Conductivity input (analogue): Measuring range with Sensor SE 202: Sensor SE 204: 2-electrode sensors: 4-electrode sensors: 0.01 to 200ìS/cm 1ìS/cm to 500mS/cm 0.1ìS x c to 200mS x c 0.1ìS x c to 1000mS x c Temperature input: Measuring range with NTC 30 kÙ: Measuring range with Pt 1000: -20 to +120°C -40 to +250°C Conductivity input, Memosens: Measuring range Sensor SE 215 MS: 10ìS/cm to 20mS/cm Conductivity input: Temperature compensation: nLF: linear 0 to 20%/K, ref. temp. adjustable 0 to 120 °C Memosens input, oxygen (optical): Saturation: Concentration: 0.000 to 1000.0% 000ìg/l to 100.00mg/l Partial pressure: Temperature measuring range: 0.0 to 2000mbar -20 to+150°C Power supply: Protection class acc. to DIN EN 60529: 4 x AA IP66/67 with pressure compensation Type 907 Multi Oxy Set Description 907 Multi Oxy incl. optical oxygen sensor SE 340
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com