LEAD/LT7 Megger Megger LEAD/LT7 Loop Impedance Tester Digital Loop Tester, For Use With LTW Series

ProducentMegger
Part Number

LEAD/LT7 (LEADLT7)

Specifications

Megger LEAD/LT7 Loop Impedance Tester Digital Loop Tester, For Use With LTW Series

Unit Price55,89 EUR
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionAccessory TypeDigital Loop Tester For Use WithLTW Series Product Details Megger MFT1500 Series The MFT1500 series has all the essential features necessary for testing Domestic, Commercial and Industrial fixed wiring in accordance with BS7671 and European Standard EN61557. The unique design allows it to be operated on the floor, a ledge, hung around the neck with the supplied neck strap, or held in the hand. The hand strap increases operational comfort and security with all the test functions easily to hand. The backlit display and selector dial allow for use in difficult low-light conditions.Patented Megger Digital/Analogue Arc display provides both digital readout and indication of fluctuating readingsFast 200mA continuity test commences the moment the test probes touch the circuit with fast response buzzer enabling time saving, hands free testingNon-tripping loop impedance test (15mA) provides a 3-wire non-tripping 0.01Ω loop test designed to prevent RCD trippingHigh current loop impedance test (25A) provides a fast loop test where no RCD is fitted, or for Ze measurement on the incoming side of an RCDProspective fault current ranges (25A test)DC sensitive RCD testRCD Ramp test displays the actual trip current on all RCD ranges. Ideal for identifying nuisance tripping RCDsAC/DC Voltmeter independent of any other test functions, eliminating the need to carry a separate multimeterIlluminated switch probe for single-handed operation and test status indication. Includes remote test button, bright white LED torch (1500mcd), red/green status LEDs and interchangeable probe tipsVisible and audible safety warnings. If live voltages exist on a circuit during insulation or continuity testing the voltage is displayed on the screen. If this voltage exceeds a safe level, the MFT1502 inhibits further testing and a warning beeper sounds for extra safety10mA to 1000mA RCD test ranges with both 0° and 180° phase angleAuto Discharge: Safely discharges system after insulation test preventing accidental shock from a stored charge on a long cable during or after disconnectionShuttered test lead sockets permit only the correct test lead combinations to be connected for safe testingRubber over-moulded case and lid provides a secure comfortable hold, whilst providing maximum protection with IP54 weather proof ratingDimensions 150 x 85 x 235 HxWxD (mm) MFT1552 Additional features:Auto RCD testSelecting the Auto RCD feature starts the RCD test current cycle of Ix0.5, Ix1 and Ix5. Resetting the tripped RCD automatically continues the test sequence. Test results can be recalled on the MFT1552 once completed Supply Voltage range   Voltage ac (Accuracy) 0 to 500 V 50//60 Hz (±2% ±2 digits) Voltage dc 0 to 500 V (±2% ±2 digits) Note Polarity indicated above 10 V Insulation test ranges (to EN 61557-2)   Short circuit current 250 V / 500 V / 1000 V 0.1 to 99.9 MΩ / 299 MΩ / 499 MΩ Measurement Accuracy ±2% ±2 digits up to 99MΩ Output Voltage 250V, 500V & 1 kV @ 1mA (BS7671 HD384 & IEC364) Output Voltage variation +20% to 0% @ rated load or less Live circuit warnings   Insulation / Continuity 25 V threshold / >15 V threshold Insulation   Phase to Earth >280 V visual, audible and test inhibit Continuity (to EN 61557-4)   Range (Accuracy) 0.01 to 99.9 Ω (±2% ±2 digits)100 Ω to 99.9 kΩ (±5% ±2 digits) Buzzer   Selectable limits of 2 Ω, 5 Ω, 10 Ω, 20 Ω, 50 Ω, 100 Ω Open circuit voltage 4 to 5 Vdc Test current >200 mA @ 2 Ω Test Lead null Up to 9.99Ω (zero uses test button) Loop test ranges (to EN 61557-3)   25A Single Phase (Line / Earth)   Range (Accuracy) 0.01 to 9.99 Ω (± 5% ± 0.03 Ω)10 to 89.9 Ω (± 5% ± 0.5 Ω)90 to 899 Ω (± 5% ± 5 Ω)900 to 3 kΩ (± 5% ± 20 Ω) Supply 55 to 280 V 45 Hz to 65 Hz 25A Phase to Phase (Line / Line)   Range (Accuracy) 0.01 to 19.99 Ω (± 5% ± 0.03 Ω) Supply 55 to 480 V 45 Hz to 65 Hz 15mA Low current loop (no trip)   Range (Accuracy) 0.01 to 2 kΩ (± 5% ± 0.03 Ω ± Noise Margin) Supply 55 to 270V 45 Hz to 65 Hz Prospective Short-circuit Current PSC   Ranges 1 to 199 A, 0.02 to 1.99 kA, 2 to 19.9 kA Prospective fault current = Nominal V / Loop R (Accuracy is determined from the loop test) Supply 100 to 270 V 45 Hz to 65 Hz RCD ranges (to EN 61557-6)   Ranges 1000 mA, 500 mA, 300 mA, 100 mA, 30 mA, 10 mA Type 0.5xI, 1xI, 5xI (I = RCD rated current) Current Accuracy 0.5xI: -8% to -2%I & 5xI: +2% to +8% DC Sensitive A DC test current at 0.5xI, 1xI, 5xI Ramp A ramp test that displays actual trip current Ramp Current Intrinsic Accuracy ± 3% Trip-time Accuracy ± 1% ± 1 ms Safety   Double insulated to Installation Category III 300 V phase to earth, 500 V phase to phase Meter to IEC1010-1:2001, probe to IEC1010-031:2002 Note RS is an authorised Megger distributor. Purchased though RS this product is eligible for the Megger extended 3 Year warranty Supplied with Instruction booklet, 3 wire mains test lead set, mains plug test lead, illuminated switched probe, instrument/document carry case. 8 AA & 1 PP3 alkaline batteries. Megger Multifunction Installation Testers
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com