OSR-24HRFN1 OLYAIR wall split air conditioner

ProducentOLYAIR
Part Number

OSR-24HRFN1 (OSR24HRFN1)

Specifications

wall split air conditioner

Unit Price
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionCondition: New Brand Name: OLYAIR Place of Origin: Guangdong, China (Mainland) Use: Room Power Source: Electrical Power Type: AC Type: Split Wall Mounted Air Conditioners Cooling/Heating: Cooling/Heating Certification: CB, CE, EMC, EMF, GS, RoHS Capacity (btu): 24000 COP: 4.0 EER: 6.1 Power (W): 6400 Voltage (V): 220 Model Number: OSR-24HRFN1 Control type: Remote Control Energy Class: A++ Compressor: toshiba Refrigerant: R410a Voltage: 220-240V/50Hz Seer: 6.1 SCOP: 4.0 Class Rating: A++ OEM: Yes Remote control: Yes Packaging & Delivery Packaging Details: As standard indoor and outdoor carton design Delivery Detail: 35 working days Eurovent Supreme Energy Efficiency A++ SCOP4.0 lower noise 24000btu wall split air conditioner Product Description Wall Split Air Conditioner Specification Sheet ModelOS-24HRFN1Power supplyPh-V-Hz220-240V~ 50Hz, 1PhRated CoolingCapacity Btu/h22000(7240~24640)Cooling Power input W171~2780Cooling Current A0.74~12.09Rated HeatingCapacity Btu/h25000(4600~30000)Heating Power input W235~3140Heating Current A1.02~13.65Seasonal CoolingPdesignckW6.4SEERW/W6.1Energy Efficiency Class A++Heating(Average )PdesignhkW5.2SCOPW/W4.0Energy Efficiency Class A+Tbiv℃-7Heating(Warmer )PdesignhkW7.1SCOPW/W4.8Energy Efficiency Class A++Tbiv℃5Tol℃-15Moisture Removal L/h2.3Max. input consumption W3100Max. current A14.5Starting current A----CompressorModel DA150S1C-20FZType Twin-rotaryBrand TOSHIBA Capacity Btu/h15286Input W1150Rated current(RLA) A9.7Locked rotor Amp(LRA) A----Thermal protector KSD301Thermal protector position EXTERNALCapacitor uF---Refrigerant oil/oil charge mlESTER OIL VG74/500Indoor fan motorModel WZDK58-38GBrand ShibauraOutput W58Capacitor uF- -Speed(Hi/Mi/Lo)r/min1180 / 1100 / 900Indoor coila.Number of rows 2b.Tube pitch(a)x row pitch(b) mm21x13.37c.Fin spacing mm1.3d.Fin type (code) Hydrophilic aluminiume.Tube outside dia.and type mmΦ7, innergroove tubef.Coil length x height x width mm780x336x26.74g.Number of circuits 4Indoor air flow (Hi/Mi/Lo)m3/h1150/1070/880Indoor sound pressure level (Hi/Mi/Lo)dB(A)49/43/36Indoor sound power level (Hi)dB(A)62Indoor unitDimension(W*D*H)mm1045x235x315Packing (W*D*H)mm1135x395x315Net/Gross weight Kg12/15.2Outdoor fan motorModel WZDK50-38GBrand ShibauraOutput W50Capacitor uF- -Speed r/min800Outdoor coila.Number of rows 2b.Tube pitch(a)x row pitch(b) mm25.4x22c.Fin spacing mm1.4d.Fin type (code) Hydrophilic aluminiume.Tube outside dia.and type mmΦ9.52,innergroove tubef.Coil length x height x width mm766x660x44g.Number of circuits 4Outdoor air flow m3/h2700Outdoor sound pressure leveldB(A)60Outdoor sound power level dB(A)67Outdoor unitDimension(W*D*H)mm845x320x700Packing (W*D*H)mm965x395x755Net/Gross weight Kg47 / 50Refrigerant Type R410AGWP 1975Charged quantityKg1.95Design pressure MPa4.2/1.5Refrigerant pipingLiquid side/ Gas side mm(inch)Φ9.52/Φ15.9(3/8"/5/8")Max. refrigerant pipe length m30Max. difference in level m20Connection wiring 2.5(Optional)Plug type --Thermostat type Remote ControlOperation temperatureIndoor(cooling/ heating)℃17~32/0~30 Outdoor(cooling/heating)℃-15~50/-15~30Application area m232-53Qty’per 20’ /40’ /40'HQ 69/140/160 Features: Mute OperationOn the basis of low noise air duct system and quiet design, you can shut off the AC beep and display by pressing mute operation to create a super quiet environment. Selectable Control ModesApart from conventional remote control, Aurora split provide a variety of optional, including wired control, front desk control and central control.Optional functions: (If you need below add functions, please let me know) 1. Active carbon Filter 2. Photocatalyst Filter 3. Catechin Filter 4. Vitamin-enriching Filter 5. Nano Silver Filter 6. Air Ionizer Our Services 1. Olyair Appliances insist high quality products reach every clients are safe without worry, so we will fully test each pc of product before leave factory. 2. As HVAC products we provide three year warranty for whole unit and compressor all use famous brand like toshiba, rechi etc. and it lasts five years warranty also. 3. Each full container we will free to combine with 0.5%-1% spare parts based on each products request. 4. Olyair Provide OEM service which will in responsible for design the indoor and outdoor carton box. If you need have own panel design reqiuest just contact us we will ask engineer to give a strong idea for your long term development. 5. In general, when we receive your inquiry message, our information dept will send related colleage in the first time. So you will receive a reply within one hour. And if no any response, please contact our service team or visit our web to get some contact information. 6. We thank you for each client to read our any products in the web, so please let both of us value time, before send inquiry. please consider the products and it's specification you really need. Sometimes, some inquiry no any subject and don't confirm what they want, but just request to inform the payment terms and MOQ which made us difficult in reply an inquiry. Packaging & Shipping Wall Split Packing Window Packing Carton: Floor Standing Packing: Company Information FAQ 1. Why the heating of the air conditioner does not function? Answer: Our remote control is designed to have both ‘cooling only’ mold and ‘cooling & heating’ mold. Users need to activate either the ‘cooling only’ mold or the ‘cooling & heating’ mold. If ‘cooling only’ mode is activated, the heating function of the air conditioner will not work, it will starting heating up the room temperature only when you turn it into ‘cooling & heating’ mold. The way of setting is demonstrated in detail in the user’s manual. 2. Why the air conditioner does not blow out hot air until several minutes after it is activated? Answer: This is because when the heating mold just started, the temperature of evaporator is relatively low and the wind blow out would be cool. Therefore, there has designed a function of cool air protection, which will stop the indoor fan from working until the evaporator reach the set temperature. Thus, there will not be any wind blow out at the beginning. 3. Why the air conditioner does not work for the first 3 minutes, after it is restarted after a sudden power lost? Answer: This is because our air conditioning has been set up with the power lost memory function (AUTO - RESTART), when suddenly power off and then immediately power on, the air conditioner will operate according to the same setting before the power off. Therefore, in order to prevent the impact of imbalance system to the compressor on its startup, the compressor will re-start operating 3 minutes delay. Thus, the condition will not either heat up or cool down the room temperature in these 3 minutes. 4. Why the capacity of new air condition seemed not strong enough to cool down the room temperature? Answer: There could be various reasons:1) The capacity is insufficient, professional will be necessary for checking.2) Wrong mode of air conditioner is brought, as the choice of models has a direct relationship with the following conditions:A. The area of the room.B. The cooling load of the room. It is related to the heat leakage, which is affected by the thermal insulation of room wall, large glass window and no. of heating source such as high voltage home appliances. The heat leakage will also be affected in places such as dining room and living room.To our experience, capacity of air conditioner = room area X cooling load, cooling load can be between 160 to 220, depend on the heat leakage. For example, if there are not any large voltage home appliances and the thermal insulation is ok, the cooling load of a single room can be estimated as 160, and 170 for a double room, 200 for a living room and 220 for a dining room. Commercial areas should be estimated according to real situations. Our client from Euro union Countries should know below request before order air conditioner into your country. In the lastest 2013, July, Euro union countries has below: 1.Austria2.Belgium3.Bulgaria4.Cyprus5.Croatia6.CzechRepublic7.Denmark8.Estonia9.Finland10.France11.Germany12.Greece13.Hungary14.Ireland15.Italy16.Latvia17.Lithuania18.Luxembourg19.Malta20.Netherlands21.Poland22.Portugal23.Romania24.Slovakia25.Slovenia26.Spain27.Sweden28.United Kingdom 1. As EU requirement on air conditioner and single duct and double duct portable air conditioner is ERP standard. And the energy efficiency will higher and higher which move step by step. Some client if not in HVAC region may not be very clear the policy. Below chart in each degree to show you how different on the new ERP stanard compare old EER rating. Energy label Difference: Olyair models from residential to commercial are reaching New class A ranking, the highest level that is now shown on energy label in Europe union. New Energy Labelling Requirement (EU) 626/2011• Three climate zones for heating (Average zone is mandatory, warmer and colder zone are voluntary) • Seasonal efficiency (performance based on multiple part loads calculation) Sound power level• Rated efficiency indicates performance only at a rated condition.Seasonal efficiency indicates performance at an entire cooling and heating season, which better matches the actual operation. High Efficiency
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com