DFT.990.RS Parker Parker 2 → 150 L/min Cable Plug Analogue Flow Controller, 24 V dc 3.5 Digit LED

ProducentParker
Part Number

DFT.990.RS (DFT990RS)

Specifications

Parker 2 → 150 L/min Cable Plug Analogue Flow Controller, 24 V dc 3.5 Digit LED

Unit Price609,65 EUR
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionControl OutputAnalogue Display Screen3.5 Digit LED Electrical ConnectionCable Plug Maximum Flow Rate2 → 150 L/min Pipe Diameter Range1 in Supply Voltage24 V dc Product Details Combined Liquid Flow Transducer/Transmitter Fluid passes through internal flow straighteners, to stabilize turbulence, before impacting on the vaned turbine rotor which rotates at a speed proportional to the flow rate. The rotor vanes have stainless steel tips which are detected by a sensor mounted externally to the glass tube. Model 1Polyester body and borosilicate glass tube; acetal bearings and nitrile seal materialAccuracy ±2% of indicated flowOperating temperature range 5 to 60°C (water) 80°C (oil)Port connection: 1in. BSP parallel threadWork in any plane and accept reverse flowDimensions (mm): H100 x W42 x L196Converts the detected pulses to a 4-20mA output signal, proportional to the flow rateSupplied calibrated to 4-100 l/min. (may be user recalibrated up to a maximum of 150 l/min.Easy to installGives a pulse output proportional to flow rateIdeal for use in totalising/latching applications when used with a compatible counterSupplied calibrated to 2-150 l/min. (NOT user adjustable) Model 2 Inline Flow Transducers
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com