Producent | PICO TECHNOLOGY | Part Number | PP707 (PP707) |
Specifications | Pico Technology PP707 Data Logger +70 °C 90%RH 5V |
Unit Price | 257,86 EUR |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | AlarmYes Best Humidity Measurement Accuracy±10 % Best Temperature Measurement Accuracy±2 °C Dimensions77 x 70 x 23mm Height23mm Humidity Measurement Resolution0.2% IncludesExtension Cable, Humidity Sensor, pH Electrode, Scope Probe, Software, Temperature Sensor x 2, USB Cable, User Manual Interface TypeUSB 2.0 Length77mm Maximum Humidity Measurement90%RH Maximum Temperature Measurement+70 °C Maximum Voltage Measurement5V Measurement ParametersDigital I/O, Humidity, Light, pH, Pulse, Resistance, Sound, Temperature Model Number pPP707 Number of Input Channels14 Power SourceMains Temperature Measurement Resolution0.1°C Weight60g Width70mm Product Details USB DrDAQ® 2011 Data Logging Kit - PP707 While the USB DrDAQ DrDAQ data logger unit (RS 749-1914) comes with many built-in sensors, the USB DrDAQ Data Logging Kit PP707 (RS 749-1917) contains additional sensors and probes to enable many other measurments to be taken, therefore allowing further experiments to take place immediately. Channel Range Resolution Accuracy pH (BNC) 0 to 14 pH 0.02 pH Sensor-calibration dependent Redox/ORP (Oxidation/Reduction)(BNC shared with pH) ±2 V @1012 Ω 1.2 mV Sensor-calibration dependent Resistance (screw terminal) 0 to 1 MΩ 250 Ω @ 10 k 5% External sensors (3 x FCC68 4/4) Measure 0 to 2.5V(Also supply power to external sensors and identify sensor type via ID resistor) 0.1 mV 1% Oscilloscope spectrum analyser channel (BNC) ±1.25 V, ±2.5 V, ±5 V, ±10 V@1M Ω 8 bits ±3% (DC) Sound waveform ±100 ±0.2 Not calibrated Sound level 55 to 100 dBA 1 dBA 5 dBA Temperature -10 to +70 °C (+14 to 158 °F) 0.1 °C @ 25 °C (32.2 °F @ 77°F) 2 °C @ 25 °C (35.6 °F @ 77°F) Light 0 to 100 0.1 Not calibrated 20kHz Arbitrary Waveform generator ±1.5 V amplitude plus ±1.5 V offset 10-bit 3% Digital I/O 4 channels 0 to 5V TTL compatible NA NA Supplied with USB DrDAQ data logger boardpH electrodeDr DAQ 2metre temperature sensorsDrDAQ humidity sensorSoftware CDUSB Installation Guide3m sensor extension cableScope probe x1 / x10 switchableUSB2 cable, 1.8 metre, blue Dr DAQ Environmental Data Logger Dr DAQ represents a breakthrough in data logging. Simply plug Dr DAQ into the parallel port of any PC, run the supplied software and you are ready to collect and display data. Everything required is supplied: Dr DAQ uses power from the PC so no batteries are required. Dr DAQ is an ideal tool for engineers or can be at the heart of hundreds of educational science experiments.As well as the built-in sensors, Dr DAQ has two sockets for external sensors. When a sensor is plugged in to Dr DAQ the software detects it and automatically scales readings. For example if a temperature sensor is plugged in readings are displayed in °C. Details are provided to allow users to develop their own sensors. Very low cost data loggerOn board sensors for light, sound and temperatureISKS/s enables Dr DAQ to capture fast signals (e.g. sound waveforms)Built-in sensors for light, sound and temperatureSockets for external sensorsMeasures pH - just plug in any standard electrodeOutput for control experimentsSimply plug into your PC and measure. PicoLog (data logging) and PicoScope (oscilloscope and spectrum analyser) software included Dr DAQ Built-in Sensors Temperature is sensed using a precision Thermistor. It can measure over the range 0 to 70°C with a resolution of 0.1°C (at 25°C)The light sensor is designed for measuring ambient light levels. It has a fast response so can also be used to measure the flicker of lights or computer monitorsThe internal microphone measures both sound level and sound waveforms. Sound level is 'A law' weighted to match the response of the human ear and can be measured over the range 55 to 100dBA. Sound waveforms can be displayed in both the time (oscilloscope) and frequency (spectrum analyser) domainVoltage (0 to 5V) and Resistance (0 to 1MΩ) can be measured using the screw terminal connectorsA digital output and a LED are also provided for control/alarm purposes. These can be set on/off using threshold limits on any channel |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|