Producent | Rs | Part Number | 6864-0001 (68640001) |
Specifications | RS 686 Series Momentary Air Switch, SURFACE Mounted |
Unit Price | 14,43 EUR |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | Manufacturer Series686 OperationNO/NC TypeMomentary Product Details Air Operated Switches, 2-Pole Element, Surface Mount The momentary action switch unit incorporates two SPDT microswitch contacts, one switch operating before the other, i.e. an increase in applied pressure on the actuator is required to operate the second switchThe alternate action switch unit incorporates two SPDT microswitch contacts, acting simultaneouslyEach switch is rated at 15 A, 250 V ac. Mounted by four No. 4 self-tapping screwsOperating pressure 1.2 psiMaximum pressure 15 psi RS, Professionally Approved Products, gives you professional quality parts across all product categories. Our range has been testified by engineers as giving comparable quality to that of the leading brands without paying a premium price. Note The mounting screw length must not exceed 6mm otherwise the bellows may be punctured. Actuators, Switch Elements, Tubing & Accessories The air operated switch system offers enhanced safety in hazardous areas by allowing remote operation of electrical circuits. The actuator is a bellows which, when compressed moves air down the air tubing to the switch element. This compressed air then expands a bellows in the switch, which operates the electrical contacts. When used in wet environments or where electrical switching would be dangerous due to arcing, the switch and all electrical wiring can be located outside the hazardous area giving the operator total electrical isolation for the equipment.,Such applications include: Battery charging rooms, laboratories, garages, or wherever explosive gases, vapours or powders may exist.,When assembled the air switch and actuator form a sealed system, therefore temperature variation will cause pressure changes, which can in extreme cases affect the performance of the switch.,To prevent this the total volume of the system must be kept below a critical value for a given temperature range and, to this end, a maximum length of air tubing (and hence volume) can be given for any combination of switch and actuator. The additional data tables give these lengths in metres; for moderate and extreme temperatures. Additional Data - Max Tube Length (m) @ +10 to +30°C Operating Temperature Switch Switch Switch Switch Switch Switch 316-951 317-320 319-742 319-758 319-708 & 319-720 319-714 & 319-736 Actuator - - - - - - 316-945 32.0 11.2 5.0 3.5 39.3 21.6 317-718 16.0 7.2 5.0 3.5 16.4 11.2 317-055 11.2 4.0 3.0 2.0 12.8 8.0 317-061 - - - - - - 317-730 16.8 6.4 6.0 4.0 12.8 8.8 317-746 - - - - - - Additional Data - Max Tube Length (m) @ –10 to +50°C Operating Temperature Switch Switch Switch Switch Switch Switch 316-951 317-320 319-742 319-758 319-708 & 319-720 319-714 & 319-736 Actuator - - - - - - 316-945 10.4 3.6 1.7 1.2 13.0 7.0 317-718 5.2 2.4 1.7 1.2 5.5 3.6 317-055 2.8 1.2 1.0 0.7 3.3 2.0 317-061 - - - - - - 317-730 4.0 2.8 2.0 1.3 2.8 2.8 317-746 - - - - - - |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|