6EP19312FC42 Siemens DIN Rail Mount UPS Power Supply, 22 → 29V dc Input, 22 → 28.5V dc Output, 2.5kW, 42.6A
| |
|
Producent | Siemens | Part Number | 6EP19312FC42 (6EP19312FC42) |
Specifications | DIN Rail Mount UPS Power Supply, 22 → 29V dc Input, 22 → 28.5V dc Output, 2.5kW, 42.6A |
Unit Price | 449,97 EUR |
Minimum Order Quantity | 1 |
Tariff No. | |
Lead Time | |
Weight and Dimension | |
Description | CommunicationsUSB Current Rating42.6A Depth125mm Dimensions125 x 102 x 125mm Input Voltage22 → 29V dc Length125mm Maximum Temperature+60°C Minimum Temperature0°C Mounting TypeDIN Rail Mount Output Voltage22 → 28.5V dc Power Rating2.5kW Weight1.1kg Width102mm Product Details DC UPS uninterruptible power supply Absolute uninterruptible mains bufferingLong battery life through integrated battery managementHigh availability through extensive protection and monitoring functionsStatus signals via green/yellow/red LED and floating relay contactsOptional status signals available via serial or USB interfaceAutomatic restart support of industrial PCsClass B radio interference suppression and high interference resistanceThe combination of primary switching controller, DC UPS module and battery module forms an uninterruptible power supply. Suitable for all applications where sudden mains power interruptions cause data loss, incurring high costs. DC-UPS 6 A module 15 A module 40 A module Nominal input voltage DC 24 V Voltage range DC 22 → 29 V Max input current 6.6 A 16 A Battery switching threshold 22.5 V, adjustable 22 → 25.5 V Mains buffering: battery-dependent: with 3.2 Ah battery (+25°C) after approx. 10 min. at 6 A approx. 45 sec. at 15 A – with 7 Ah battery (+25°C) after approx. 30 min. at 6 A approx. 7min. at 15 A approx. 2 min. at 40 A Output UA1: Voltage with Mains operation Input voltage - approx. 0.5 V Voltage with buffer operation DC 27 V (off-load voltage) ...19 V (low voltage disconnect) Output current 0 → 6 A 0 → 15 A 0 → 40 A Short-circuit protection electronic current limit Output UA2: Charge end voltage 27 V , adjustable 26.3 → 29.3 V Charge current 0.2/0.4 A 0.35/0.7 A 1.0/2.0 A Monitoring Low voltage disconnect, wire break, battery life, charge status Status signals Mains operation, buffer operation, alarm Operating temperature 0 → +60°C Mounting on standard mounting railDIN EN 50022, 35 x 15 / 7.5 Dimensions (WxHxD) 50 x 125 x 125 mm 102 x 125 x 125 mm Weight approx. 0.45 kg 1.1 kg Battery module Dimensions Ambient temperature: Weight 24 V/1.2 Ah 96 x 106 x 108 mm +5 → +40°C 2.0 kg 24 V/3.2 Ah 190 x 151 x 82 mm +5 → +40°C 3.5 kg 24 V/7 Ah 186 x 168 x 121 mm +5 → +40°C 6.0 kg 24 V/12 Ah 253 x 118 x 121 mm +5 → +40°C 9.0 kg Approvals CE, UL/cUL Switch Mode - Siemens (Sitop) |
Datasheets | |
E-shop Coming Soon
| |
E-shop Coming Soon
| |
Related Parts
| |
|