UPS-1500X VMARK uninterruptible power supply

ProducentVMARK
Part Number

UPS-1500X (UPS1500X)

Specifications

uninterruptible power supply

Unit Price16,62 EUR
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionPlace of Origin: Guangdong, China (Mainland) Brand Name: VMARK Model Number: UPS-1500X Phase: Single Phase Protection: Unbalanced Loads Weight: 22.0 kg Output Voltage: 220/ 230/ 240/ 110/ 120 Vac Type: Standby Application: Computer Certification: CE & ISO:9001 Packaging & Delivery Packaging Details: 1pc/gift box Delivery Detail: 30~40 days UPS An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment Offline/ Standby UPS The offline/standby UPS (SPS) offers only the most basic features, providing surge protection and battery backup. The protected equipment is normally connected directly to incoming utility power. When the incoming voltage falls below or rises above a predetermined level the SPS turns on its internal DC-AC inverter circuitry, which is powered from an internal storage battery. The UPS then mechanically switches the connected equipment on to its DC-AC inverter output. The switchover time can be as long as 25 milliseconds depending on the amount of time it takes the standby UPS to detect the lost utility voltage. The UPS will be designed to power certain equipment, such as a personal computer, without any objectionable dip or brownout to that device. Offline/ Standby UPS Diagram UPS-1500XSpecificationsMicroprocessor control. Automatic voltage regulation. Emergency power backup. Short Circuit & Overcharge Protection. Model No.1500VA/900WTechnologyLine InteractiveINPUTVoltage Range160V~250V AC / 90V~140V±5V ACNominal Voltage220V/230V/240V/110V/120V ACFrequency45~65HzMax. Current5.6AOUTPUTNominal Voltage220/230/240±2%VACMax. Current4.5AVoltage Range(Normal Mode)220V/230V/240V/110V/120V AC ±10%Voltage Range(Battery Mode)220V/230V/240V/110V/120V AC ±10%(Modified Sine Wave)Frequency(Normal Mode)Synchronized(Sine Wave)Frequency(Battery Mode)50/60Hz±0.5HzWaveformModified Sine WavePower Factor0.9Efficiency>90%Transfer Time<10msBATTERY &RUNTIMEBattery TypeMaintenance-free Sealed Lead-acid Battery, LeakproofIncluded BatteryModules4*12V/7.0AhRuntime(Half/Full Load)Full Load4.0 minutesHalf Load15 minutesDischarge Time4*(PC+17"Mon)>=6 minutesCharge Time≤12 Hours,Charging Up to 90%Display StatusLED (Normal,Backup,Fault)AudibleAlarmBuzzerAC Normal / Battery Mode / Battery Level / FaultBattery ModeBeeping sound every 4 secondsafter utility power fails.Beeping sound every secondif battery approaches final dischargeInterfacePort(s)PortRs-232 / USBControl SoftwareMonitor of Utility Fault,Power Failure,Battery,UPS Statu Indicator etc.Software Function1.Anlysis of Power Status, 2.Timing Controlling, 3.Monitor UPS,4.Execute UPS Self-diagnosis, 5.Automatic SaveCold-start CapabilityYesProtectionSurge Protection &FilteringHigh Voltage,Low Voltage,Surge,SpikeOverload Protection110%~130% Automatic Cut Off Output,Buzzer Beeping(Battery Mode)Battery LowVoltage Protection10V±0.2V Automatic Cut Off OutputOutput ShortCircuit ProtectionAutomatic Cut Off Output,Buzzer BeepingEMI FilterYesTel/Fax/Modem JackYesRegulatory ApprovalsCEOperatingConditionsOperatingTemperature0~40StorageTemperature-15~45Relative Humidity10%RH~95%RH,Non-condensing Troubleshooting ProblemPossible CauseAction to TakeUPS not on. LCD/VFD/LED, not lightPOWER botton was not been pushed or been pushed too shortPress the POWER button and hold more than 4 seconds.PCB failureReplace the PCB, call for serviceUPS always at battery modePower cord looseReplace the power cordAC fuse burn outReplace the AC fuseLine voltage too high, too low or black out.Normal conditionPCB failureReplace the PCB, call for serviceBuzzer continuous beepingOverloadRemove the nonessential loadsUPS does not provide expected run time, low battery warning is sound prematurely.Battery is weak due to wear or successive mains outagesAllow UPS to recharge battery for a minimum of 8 hours. If up sounds low battery warning promaturely, when retested, battery should be replaced. SAFE INDICATOR BACK ELEVATION Please select the suitable input plug or other input accessories from below listed. AC INPUT POWER CORD Please select the suitable output socket or other output accessories from below listed. AC OUTPUT SOCKET Gift Box for UPS-1500X CAUTION: Always place the regulator in a condition is: - Well ventilated- not be exposed to direct sunlight or heat source- out of reach from children- away from water, moisture, oil or grease- secure and no risk of falling About VMARK Year of establishment:1984Product:AVR, UPS, AVS, Surge Protector, Inverter, ConvertorApprovals/ Certificate:CE, RoHSBrand:VMARKProduction lines:7Factory size:25000 m2No. of staffs500No. of R&D31~40No. of engineers11~20No. of QC staffs21~30 Workshop7 production lines, max daily output 10K500 practiced workersEfficient automatic process equipmentAdvanced tesing instrumentsISO 9001 qualified assurance system Research & Development 30 yeas R & D experience in power solution600 square meters R & D laboratory equipped with state-of-the art instruments30 in-house technicians have the ability to transfer your requirement to shipping productsPrecise and organized R & D prcedure Show room7 Categories350 Models Power ProblemsOur SolutionsBlackout (Power Failure)UPSInverterVoltage Fluctuation (Over-voltage or under-voltage)Automatic Voltage Regulator (AVR)Automatic Voltage Switch (AVS)Surge, Spike, Lighting StrikesSurge ProtectorDifferent Voltage Needs Step us & down TransformerDC12V to AC220V PowerMobile Inverter Sales & Marketing90 countried and regions covered throughout the worldExperienced and fast-responsing sales teams offer you our best solutions and competitive pricesOccasionally promotion letters keep you updated of our new products and servicesFree promotion gifts and catalogues available Welcome to VMARKContinuous improvement attitudeTo help our customers remain competitive in the market with our efficient after-sales backupListening to customers whom have experienced problems and come up with practical solutions
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com