163UK-9920066 WissenschaftlichTechnischeWerkstätten Multiparameter meters, Multi, Type Multi 3420 Set C , Description incl. SenTix® 940, TetraCon® 925

ProducentWissenschaftlichTechnischeWerkstätten
Part Number

163UK-9920066 (163UK9920066)

Specifications

Multiparameter meters, Multi, Type Multi 3420 Set C , Description incl. SenTix® 940, TetraCon® 925

Unit Price
Minimum Order Quantity1
Tariff No.
Lead Time
Weight and Dimension
DescriptionMultiparameter meters, ProfiLine Multi 3410 / 3420 / 3430 There are 3 different models available: Multi 3410 : A single channel meter for pH, ORP, conductivity and DO measurement. It is particularly aimed at those users measuring one parameter but occasionally having requirements for measuring a second or third. Multi 3420 : A dual channel instrument for simultaneous measurement of two equal or different parameters Multi 3430 : A triple channel instrument for simultaneous measurement of up to three equal or different parameters Selected IDS-Sensors: SenTix® 940 : Low maintenance combined pH electrode with ATC, QSC suitable, memory for 10 calibrations, stored serial number, pH 0.000 to 14.000 (±0.004pH), temperature range 0.0 to 80.0°C, ±0.2°C SensoLyt® 900: Low maintenance polymer electrolyte pH electrode with built-in temperature sensor, pressure resistant up to 10 bar, QSC suitable, memory for 10 calibrations, saved serial number, pH 2.000 to 12.000 (±0.004pH), temperature range from 0.0 to 60.0°C, ±0.2°C SenTix® 950 : Combined pH-electrode with plastic shaft, 3 mol/l KCl, ATC, QSC-suitable, memory for 10 calibrations, stored serial number, pH 0.000 to 14.000 (±0.004pH), temperature range 0.0 to 80.0°C, ±0.2°C SenTix® 980 : Combined pH-electrode with plastic shaft, 3 mol/l KCl, ATC, platinum wire junction, QSC-suitable, memory for 10 calibrations, stored serial number, pH 0.000 to 14.000 (±0.004pH), temperature range 0.0 to 100.0°C, ±0.2°C TetraCon® 925 : Robust, general purpose 4-electrode conductivity cell with graphite electrodes incorporating integral temperature sensor. Memory for 10 calibrations, stored serial number, measuring range 10 µS/cm to 2000 mS/cm ±0.5% of value, 0.0 to 100.0°C, ±0.2°C LR 925/01 : 2-electrode stainless steel conductivity cell for low conductivities, integrated temperature sensor, flow through vessel, memory for 10 calibrations, stored serial number, measuring range 0.01 µS/cm to 200µS/cm ±0.5% of value, 0.0 to 100.0°C, ±0.2°C FDO® 925 : Extremely fast (T99 The information for meter precision refers to the sensors' built-in, electronic, measuring technology. Measurement ranges pH: -2.000 to 20.000 mV: -2.00 to +20.00 ±2500, ±1250 Oxygen measurement O2 concentration: 0.00 to 20.00 mg/l O2 saturation: 0.0 to 200.0% O2 partial pressure: 0.0 to 400% Conductivity measurement: 0.0mS/cm to 2000mS/cm in 5 mode 0.00µS/cm to 19.99µS/cm (at K=0.1cm-1) 0.000µS/cm to 2.000µS/cm (at K=0.01cm-1) Temp.: -5.0°C to +105°C Memory: manual or time controlled logger, 10000 records Power supply: 4 x 1.2V NiMH, A-Type, battery charger Type Multi 3420 Set C Description incl. SenTix® 940, TetraCon® 925
Datasheets
E-shop Coming Soon

E-shop Coming Soon
E-shop Coming Soon

E-shop Coming Soon
Related Parts
© 2015 WorldHNews.com